mirror of
https://github.com/adrianjagielak/home-assistant-futurehome.git
synced 2026-05-28 05:55:40 +00:00
Fix invalid device_class + unit_of_measurement combinations for HA 2026.5
HA 2026.5 enforces strict validation of device_class/unit_of_measurement pairs in MQTT discovery payloads. Four categories were broken: - power_factor: unit was sent as "power_factor" (the FIMP field name); HA requires the field to be omitted or empty for this device class. Fixed by normalising the display unit separately from the FIMP data-path key. - illuminance: unit "Lux" is rejected; normalise to "lx". When a sensor reports luminance as "%" (some Z-Wave devices), the illuminance device class is dropped so the entity becomes a generic sensor rather than triggering a validation error. - reactive_power (regular/export meter): unit "VAr" is rejected; HA requires lowercase "var". - reactive_power (extended meter values, e.g. p_import_react): the unit determination logic fell through to the generic power branch and sent "W"; reactive power extended values now emit "var", apparent power values emit "VA", and reactive energy values emit "kvarh". Fixes #31
This commit is contained in:
@@ -370,16 +370,25 @@ export function _meter__components(
|
||||
break;
|
||||
}
|
||||
|
||||
// Map FIMP unit names to HA-compatible unit_of_measurement values
|
||||
const haUnit =
|
||||
unit === 'power_factor' ? '' :
|
||||
unit === 'VAr' ? 'var' :
|
||||
unit === 'kVArh' ? 'kvarh' : unit;
|
||||
|
||||
const component: SensorComponent = {
|
||||
unique_id: componentId,
|
||||
platform: 'sensor',
|
||||
entity_category: 'diagnostic',
|
||||
name: friendlyName,
|
||||
unit_of_measurement: unit,
|
||||
state_class: stateClass,
|
||||
value_template: `{{ value_json['${svc.addr}'].meter.${unit}.val | default(0) }}`,
|
||||
};
|
||||
|
||||
if (haUnit) {
|
||||
component.unit_of_measurement = haUnit;
|
||||
}
|
||||
|
||||
if (deviceClass) {
|
||||
component.device_class = deviceClass;
|
||||
}
|
||||
@@ -460,16 +469,24 @@ export function _meter__components(
|
||||
break;
|
||||
}
|
||||
|
||||
// Map FIMP unit names to HA-compatible unit_of_measurement values
|
||||
const haUnit =
|
||||
unit === 'VAr' ? 'var' :
|
||||
unit === 'kVArh' ? 'kvarh' : unit;
|
||||
|
||||
const component: SensorComponent = {
|
||||
unique_id: componentId,
|
||||
platform: 'sensor',
|
||||
entity_category: 'diagnostic',
|
||||
name: friendlyName,
|
||||
unit_of_measurement: unit,
|
||||
state_class: stateClass,
|
||||
value_template: `{{ value_json['${svc.addr}'].meter_export.${unit}.val | default(0) }}`,
|
||||
};
|
||||
|
||||
if (haUnit) {
|
||||
component.unit_of_measurement = haUnit;
|
||||
}
|
||||
|
||||
if (deviceClass) {
|
||||
component.device_class = deviceClass;
|
||||
}
|
||||
@@ -510,14 +527,25 @@ export function _meter__components(
|
||||
|
||||
// Determine unit based on value name
|
||||
let unit = '';
|
||||
if (
|
||||
const isPhasePower =
|
||||
valueName.startsWith('p_') ||
|
||||
valueName.startsWith('p1') ||
|
||||
valueName.startsWith('p2') ||
|
||||
valueName.startsWith('p3') ||
|
||||
valueName === 'dc_p'
|
||||
) {
|
||||
valueName.startsWith('p3');
|
||||
if (isPhasePower && valueName.includes('_react')) {
|
||||
unit = 'var';
|
||||
} else if (isPhasePower && valueName.includes('_apparent')) {
|
||||
unit = 'VA';
|
||||
} else if (isPhasePower || valueName === 'dc_p') {
|
||||
unit = 'W';
|
||||
} else if (
|
||||
(valueName.startsWith('e_') ||
|
||||
valueName.startsWith('e1') ||
|
||||
valueName.startsWith('e2') ||
|
||||
valueName.startsWith('e3')) &&
|
||||
valueName.includes('_react')
|
||||
) {
|
||||
unit = 'kvarh';
|
||||
} else if (
|
||||
valueName.startsWith('e_') ||
|
||||
valueName.startsWith('e1') ||
|
||||
@@ -565,9 +593,9 @@ export function _meter__components(
|
||||
}
|
||||
|
||||
// Set suggested display precision
|
||||
if (unit === 'kWh') {
|
||||
if (unit === 'kWh' || unit === 'kvarh') {
|
||||
component.suggested_display_precision = 3;
|
||||
} else if (unit === 'W' || unit === 'V' || unit === 'A') {
|
||||
} else if (unit === 'W' || unit === 'V' || unit === 'A' || unit === 'var' || unit === 'VA') {
|
||||
component.suggested_display_precision = 1;
|
||||
} else if (unit === 'Hz') {
|
||||
component.suggested_display_precision = 2;
|
||||
|
||||
@@ -72,12 +72,15 @@ export function _sensor_numeric__components(
|
||||
|
||||
if (!data) return undefined;
|
||||
|
||||
const device_class = data[0];
|
||||
let device_class = data[0];
|
||||
const name = data[1];
|
||||
let unit = svc.props?.sup_units?.[0] ?? data[2];
|
||||
if (unit === 'C') unit = '°C';
|
||||
if (unit === 'F') unit = '°F';
|
||||
if (unit === 'kph') unit = 'km/h';
|
||||
if (unit === 'Lux') unit = 'lx';
|
||||
// HA rejects illuminance + %; drop device_class for percentage-reporting sensors
|
||||
if (device_class === 'illuminance' && unit === '%') device_class = undefined;
|
||||
const state_class = data[3];
|
||||
|
||||
return {
|
||||
|
||||